X

Top units


ThinkTop V50 and V70 ThinkTop V50 and V70 are valve control units, they are interchangable with prior ThinkTop versions.


Burst seat clean function During CIP, it's common to run a sequence of seat lifts, to save CIP liquid this can be optimised by using the "Burst seat clean function", this function secure full seat lift and then instantly close again, (avalable on V70).


ThinkTop V50 is for valves: Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof.
(Except special valves; Long stroke, LKLA, Air/Air and 2-step actuators)


ThinkTop V70 is for valves: Unique SSV, iSSV, SSSV, LKLA-T, SMP-BC, DV-ST, Shutter, SBV, Unique Mixproof, Long stroke, Air/Air and 2-step actuators.
(Except special valves; LKLA)


Benefits Automatic setup Automatic valve recognition Fast Auto, Live and Flex Setup 360-degree LED indication Burst clean function (V70) Interchangeable with prior ThinkTop versions


 


 


 



ThinkTop V20 ThinkTop V20 valve control unit is a reliable, cost-effective control unit. It provides standard functionality for intuitive sensing of the valve position and status, displayed on the unit’s 360° light-emitting diodes (LEDs).


 Benefits Highly accurate indication of hygienic valve positions within ± 1 mm Hygienic design based on the ThinkTop V50 and V70 Intuitive live setup for fast installation Digital, AS-I or IO-Link interfaces Compatible with Alfa Laval hygienic valves with standard mushroom connections, making it easy to upgrade older valve indication units 360-degree LED indication


 


 


ThinkTop V50
 DescriptionDenominationEl. con.Sol.Air con.Valve typePart NoAdd to cart
 IO-Link
Supply control board: 24 VDC
ThinkTop V50 IO-Link M120--6-9615 40 0419 
ThinkTop V50 IO-Link 3/2M1216mm3/26-9615 40 0420
ThinkTop V50 IO-Link 3/2M1211/4"3/26-9615 40 0421
       
 Digital PNP

Supply control board: 24 VDC
ThinkTop V50 PNP  Gland0--6-9615 40 0401 
ThinkTop V50 PNP 3/2Gland16mm3/26-9615 40 0403
ThinkTop V50 PNP 3/2Gland11/4"3/26-9615 40 0405
ThinkTop V50 PNP M120--6-9615 40 0402
ThinkTop V50 PNP 3/2M1216mm3/26-9615 40 0404
ThinkTop V50 PNP 3/2M1211/4"3/26-9615 40 0406
       
 AS-Interface v2.1 / 31 node

Supply control board: 29.5-31.6 VDC
ThinkTop V50 AS-iv2.1  Gland0--6-9615 40 0407 
ThinkTop V50 AS-iv2.1 3/2Gland16mm3/26-9615 40 0409
ThinkTop V50 AS-iv2.1 3/2Gland11/4"3/26-9615 40 0411
ThinkTop V50 AS-iv2.1M120--6-9615 40 0408
ThinkTop V50 AS-iv2.1 3/2M1216mm3/26-9615 40 0410
ThinkTop V50 AS-iv2.1 3/2M1211/4"3/26-9615 40 0412
       
 AS Interface v3.0 / 62 node

Supply control board: 29.5-31.6 VDC
ThinkTop V50 AS-iv3.0 Gland0--6-9615 40 0413 
ThinkTop V50 AS-iv3.0 3/2Gland16mm3/26-9615 40 0415
ThinkTop V50 AS-iv3.0 3/2Gland11/4"3/26-9615 40 0417
ThinkTop V50 AS-iv3.0M120--6-9615 40 0414
ThinkTop V50 AS-iv3.0 3/2M1216mm3/26-9615 40 0416
ThinkTop V50 AS-iv3.0 3/2M1211/4"3/26-9615 40 0418
       

ThinkTop V70
 DescriptionDenominationEl. con.Sol.Air con.Valve typePart NoAdd to cart
 IO-Link
Supply control board: 24 VDC
ThinkTop V70 IO-Link M120--6-9615 40 0301 
ThinkTop V70 IO-Link 3/2M1216mm3/26-9615 40 0302
ThinkTop V70 IO-Link 3/2M1226mm3/26-9615 40 0304
ThinkTop V70 IO-Link 3/2M1236mm3/26-9615 40 0306
ThinkTop V70 IO-Link 5/2M1216mm5/26-9615 40 0308
ThinkTop V70 IO-Link 3/2M1211/4"3/26-9615 40 0303
ThinkTop V70 IO-Link 3/2M1221/4"3/26-9615 40 0305
ThinkTop V70 IO-Link 3/2M1231/4"3/26-9615 40 0307
ThinkTop V70 IO-Link 5/2M1211/4"5/26-9615 40 0309
       
 AS-Interface v2.1 / 31 node

Supply control board: 29.5-31.6 VDC
ThinkTop V70 AS-iv2.1 Gland06mm3/26-9615 40 0101 
ThinkTop V70 AS-iv2.1 3/2Gland16mm3/26-9615 40 0103
ThinkTop V70 AS-iv2.1 3/2Gland26mm3/26-9615 40 0107
ThinkTop V70 AS-iv2.1 3/2Gland36mm3/26-9615 40 0111
ThinkTop V70 AS-iv2.1 5/2Gland16mm5/26-9615 40 0115
ThinkTop V70 AS-iv2.1 3/2Gland11/4"3/26-9615 40 0105
ThinkTop V70 AS-iv2.1 3/2Gland21/4"3/26-9615 40 0109
ThinkTop V70 AS-iv2.1 3/2Gland31/4"3/26-9615 40 0113
ThinkTop V70 AS-iv2.1 5/2Gland11/4"5/26-9615 40 0117
ThinkTop V70 AS-iv2.1M120--6-9615 40 0102
ThinkTop V70 AS-iv2.1 3/2M1216mm3/26-9615 40 0104
ThinkTop V70 AS-iv2.1 3/2M1226mm3/26-9615 40 0108
ThinkTop V70 AS-iv2.1 3/2M1236mm3/26-9615 40 0112
ThinkTop V70 AS-iv2.1 5/2M1216mm5/26-9615 40 0116
ThinkTop V70 AS-iv2.1 3/2M1211/4"3/26-9615 40 0106
ThinkTop V70 AS-iv2.1 3/2M1221/4"3/26-9615 40 0110
ThinkTop V70 AS-iv2.1 3/2M1231/4"3/26-9615 40 0114
ThinkTop V70 AS-iv2.1 5/2M1211/4"5/26-9615 40 0118
       
 Digital PNP

Supply control board: 24 VDC
ThinkTop V70 PNP  Gland0--6-9615 40 0001 
ThinkTop V70 PNP 3/2Gland16mm3/26-9615 40 0003
ThinkTop V70 PNP 3/2Gland26mm3/26-9615 40 0007
ThinkTop V70 PNP 3/2Gland36mm3/26-9615 40 0011
ThinkTop V70 PNP 5/2Gland16mm5/26-9615 40 0015
ThinkTop V70 PNP 3/2Gland11/4"3/26-9615 40 0005
ThinkTop V70 PNP 3/2Gland21/4"3/26-9615 40 0009
ThinkTop V70 PNP 3/2Gland31/4"3/26-9615 40 0013
ThinkTop V70 PNP 5/2Gland11/4"3/26-9615 40 0017
ThinkTop V70 PNP M120--6-9615 40 0002
ThinkTop V70 PNP 3/2M1216mm3/26-9615 40 0004
ThinkTop V70 PNP 3/2M1226mm3/26-9615 40 0008
ThinkTop V70 PNP 3/2M1236mm3/26-9615 40 0012
ThinkTop V70 PNP 5/2M1216mm3/26-9615 40 0016
ThinkTop V70 PNP 3/2M1211/4"3/26-9615 40 0006
ThinkTop V70 PNP 3/2M1221/4"3/26-9615 40 0010
ThinkTop V70 PNP 3/2M1231/4"3/26-9615 40 0014
ThinkTop V70 PNP 5/2M1211/4"3/26-9615 40 0018
       
 AS Interface v3.0 / 62 node

Supply control board: 29.5-31.6 VDC
ThinkTop V70 AS-iv3.0 Gland0--6-9615 40 0201 
ThinkTop V70 AS-iv3.0 3/2Gland16mm3/26-9615 40 0203
ThinkTop V70 AS-iv3.0 3/2Gland26mm3/26-9615 40 0207
ThinkTop V70 AS-iv3.0 3/2Gland36mm3/26-9615 40 0211
ThinkTop V70 AS-iv3.0 5/2Gland16mm5/26-9615 40 0215
ThinkTop V70 AS-iv3.0 3/2Gland11/4"3/26-9615 40 0205
ThinkTop V70 AS-iv3.0 3/2Gland21/4"3/26-9615 40 0209
ThinkTop V70 AS-iv3.0 3/2Gland31/4"3/26-9615 40 0213
ThinkTop V70 AS-iv3.0 5/2Gland11/4"5/26-9615 40 0217
ThinkTop V70 AS-iv3.0M120--6-9615 40 0202
ThinkTop V70 AS-iv3.0 3/2M1216mm3/26-9615 40 0204
ThinkTop V70 AS-iv3.0 3/2M1226mm3/26-9615 40 0208
ThinkTop V70 AS-iv3.0 3/2M1236mm3/26-9615 40 0212
ThinkTop V70 AS-iv3.0 5/2M1216mm5/26-9615 40 0216
ThinkTop V70 AS-iv3.0 3/2M1211/4"3/26-9615 40 0206
ThinkTop V70 AS-iv3.0 3/2M1221/4"3/26-9615 40 0210
ThinkTop V70 AS-iv3.0 3/2M1231/4"3/26-9615 40 0214
ThinkTop V70 AS-iv3.0 5/2M1211/4"5/26-9615 40 0218
       

ThinkTop V20
 DescriptionDenominationPart NoAdd to cart
 IO-Link
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
ThinkTop V20 IO-Link 6-8010018592 
   
 AS-i V3.0
Electrical connection: M12
Supply control board: 29.5 – 31.6 VDC
ThinkTop V20 AS-i V3.0 6-8010018590 
   
 Digital
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
ThinkTop V20 Digital 6-8010018591 
   
 Digital Retrofit IndiTop
Electrical connection: M12
Supply control board: 24 VDC ± 10 %
_______________________________
ThinkTop V20 Digital retro 6-8010018593 
   

 

© Copyright Tetra Pak ®
Disclaimer