X

Flowmeter, Coriolis


Promass E 100 and E 300 Application Simultaneously direct mass and density measurement and any liquid application for standard dairy and beverage applications.
Example of applications:
Milk, cream, chocolate, oil, fruit juice, puree etc RO water or low conductive liquids Gas measurement application such as CO2 for CSD process Benefits High performance with optimum cost Universal coriolis meter for standard applications SS housing with large display Polished measuring tubes with all hygienic approvals


Promass F 100Application Welded sensor for fluid temperatures up to +200°C. Application examples: Vegetable oils, animal fats and fruit concentrates. Benefits Very compact housing M12 connection 2 outputs in non-bus versions Can replace all Promass 8x series including remote versions More vibration resistent No display Suitable for CIP/SIP cleaning Sensor body in stainless steel for high sanitary safety Balanced dual-tube system for universal use in a wide range of process conditions High vibration immunity, “Fit and forget” installation, compact design, occupying very little space Measurement is independent of fluid properties Sensor body in stainless steel for high sanitary safety Additional software options available: - Batching applications - Concentration measurement Multifunctional: Simultaneous measurement of flow (mass flow, volume flow), density and temperature High accuracy: ±0.10%


 


Promass F 300 Application Simultaneously direct mass and density measurement and any liquid application that needs high accuracy and precision.
Example of applications:
- Milk, cream, chocolate, oil, fruit juice, puree etc
- Brix and concentration measurement
- High accuracy demand for gas measurement application such as CO2 for CSD process
Benefits Touch button screen Multi analog output (optional) Remote display (optional) Atex approval available (optional)


 


Promass Q 300 Application Premium density accuracy measurement as well as entrained gas applications such as ice cream, milk cream, standardization and brix measurement. Benefits Ultra high density accuracy ±0.0002 g/cm³ High accuracy flow measurement ± %0.1 Real-time compensation error compensation for air bubble content Less pressure drop comparison with typical bended measuring tubes Wider operable flow rate Suitable for CIP/SIP cleaning Sensor body in stainless steel for high sanitary safety


Promass E 100
 DescriptionDenominationPart NoAdd to cart
 Clamp connection / Profinet
Profinet IO
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
Polished tubes 0.76um
3A certified
Flowmeter E100 1" 0-18.000 kg/h 90532-0167 
Flowmeter E100 1-1/2" 0-45.000 kg/h90532-0168
Flowmeter E100 2" 0-65.000 kg/h90532-0169
Flowmeter E100 3" 0-180.000 kg/h90532-0170
   
 Clamp connection / Profinet
Profinet IO
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
Polished tubes 0.76um
EHEDG certified
Flowmeter E100 1" 0-18.000 kg/h 90532-0171 
Flowmeter E100 1-1/2" 0-45.000 kg/h90532-0172
Flowmeter E100 2" 0-65.000 kg/h90532-0173
Flowmeter E100 3" 0-180.000 kg/h90532-0174
   
 Clamp connection / Ethernet
Ethernet IP
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
Polished tubes 0.76um
3A Certified
Flowmeter E100 1" 0-18.000 kg/h 90532-0175 
Flowmeter E100 1-1/2" 0-45.000 kg/h90532-0176
Flowmeter E100 2" 0-65.000 kg/h90532-0177
Flowmeter E100 3" 0-180.000 kg/h90532-0178
   
 Clamp connection / Analog
Analog 4_20mA
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
Polished tubes 0.76um
Flowmeter E100 1" 0-18.000 kg/h 90532-0190 
Flowmeter E100 1-1/2" 0-45.000 kg/h90532-0191
Flowmeter E100 2" 0-65.000 kg/h90532-0192
Flowmeter E100 3" 0-180.000 kg/h90526-7602
   
 DIN 11864-1A union / Profinet
Profinet IO
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
EHEDG certified
Flowmeter E100 DN25 0-18.000 kg/h 90532-0159 
Flowmeter E100 DN40 0-45.000 kg/h90532-0160
Flowmeter E100 DN50 0-65.000 kg/h90532-0161
Flowmeter E100 DN80 0-180.000 kg/h90532-0162
   
 SMS union / Profinet
Profinet IO
-/+ %0.15 accuracy for mass flow
SS housing w/o display
El. connection: 2xM12
Polished tubes 0.76um
_____________________________
Flowmeter E100 SMS25 0-18.000 kg/h 90532-0163 
Flowmeter E100 SMS38 0-45.000 kg/h90532-0164
Flowmeter E100 SMS51 0-65.000 kg/h90532-0165
Flowmeter E100 SMS76.1 0-180.000 kg/h90532-0166
   

Promass E 300
 DescriptionDenominationPart NoAdd to cart
 Clamp connection
Analog version
4_20mA + 2x Confg. IO (pulse or switch)
CE and UK CA marked
-/+ %0.15 accuracy for mass flow
SS housing with display
El. connection: Gland M20
Polished tubes 0.76um
3A & EHEDG certified
Flowmeter E300 ⅜" 0-2.000 kg/h 90531-3438 
Flowmeter E300 ½" 0-6500 kg/h90531-3439
Flowmeter E300 1" 0-18.000 kg/h90531-3440
Flowmeter E300 1½" 0-45.000 kg/h90531-3441
Flowmeter E300 2" 0-65.000 kg/h90531-3442
Flowmeter E300 3" 0-180.000 kg/h90531-3443
   
 DIN 11851 union
Analog version
4_20mA + 2x Confg. IO (pulse or switch)
CE and UK CA marked
-/+ %0.15 accuracy for mass flow
SS housing with display
El. connection: Gland M20
Polished tubes 0.76um
3A & EHEDG certified
Flowmeter E300 DN08 0-2.000 kg/h 90531-3444 
Flowmeter E300 DN15 0-6500 kg/h90531-3445
Flowmeter E300 DN25 0-18.000 kg/h90531-3446
Flowmeter E300 DN40 0-45.000 kg/h90531-3447
Flowmeter E300 DN50 0-65.000 kg/h90531-3448
Flowmeter E300 DN80 0-180.000 kg/h90531-3449
   
 DIN 11864-2A Flange
Analog version
4_20mA + 2x Confg. IO (pulse or switch)
CE and UK CA marked
-/+ %0.15 accuracy for mass flow
SS housing with display
El. connection: Gland M20
Polished tubes 0.76um
3A & EHEDG certified
Flowmeter E300 DN08 0-2.000 kg/h 90531-3450 
Flowmeter E300 DN15 0-6500 kg/h90531-3451
Flowmeter E300 DN25 0-18.000 kg/h90531-3452
Flowmeter E300 DN40 0-45.000 kg/h90531-3453
Flowmeter E300 DN50 0-65.000 kg/h90531-3454
Flowmeter E300 DN80 0-180.000 kg/h90531-3455
   
 SMS union connection
Analog version
4_20mA + 2x Confg. IO (pulse or switch)
CE and UK CA marked
-/+ %0.15 accuracy for mass flow
SS housing with display
El. connection: Gland M20
Polished tubes 0.76um
3A compliant
_________________________________
Flowmeter E300 SMS25 0-2.000 kg/h 90531-3456 
Flowmeter E300 SMS25 0-6500 kg/h90531-3457
Flowmeter E300 SMS25 0-18.000 kg/h90531-3458
Flowmeter E300 SMS38 0-45.000 kg/h90531-3459
Flowmeter E300 SMS51 0-65.000 kg/h90531-3460
Flowmeter E300 SMS76.1 0-180.000 kg/h90531-3461
   

Promass F 100 - Clamp
 DescriptionDenominationPart NoAdd to cart
 Clamp - PROFINET IO
Tri-clamp process connection
PROFINET IO
Polished measuring tubes 0.76um
0.1% accuracy
2XM12 electrical connection IP69K
Ultracompact stainless steel housing
Special density application package
Flowmeter F100 1/2" 0-6500kg 90532-9445 
Flowmeter F100 1" 0-18000kg90532-9446
Flowmeter F100 1-1/2" 0-45000kg90532-9447
Flowmeter F100 2" 0-70000kg90532-9448
Flowmeter F100 3" 0-180000kg90532-9449
   
 Clamp - Ethernet IP
Tri_clamp_process_connection
Ethernet IP
Polished measuring tubes 0.76um
0.1% accuracy
2XM12 electrical connection IP69K
Ultracompact stainless steel housing
Special density application package
Flowmeter F100 1/2" 0-6500kg 90532-9450 
Flowmeter F100 1" 0-18000kg90532-9451
Flowmeter F100 1-1/2" 0-45000kg90532-9452
Flowmeter F100 2" 0-70000kg90532-9453
Flowmeter F100 3" 0-180000kg90532-9454
   
 Clamp - PROFINET IO - EHEDG
Tri-clamp process connection
PROFINET IO
Polished measuring tubes 0.76um EHEDG design
0.1% accuracy
2XM12 electrical connection IP69K
Ultracompact stainless steel housing
Special density application package
Flowmeter F100 1/2" 0-6500kg 90532-9455 
Flowmeter F100 1" 0-18000kg90532-9456
Flowmeter F100 1-1/2" 0-45000kg90532-9457
Flowmeter F100 2" 0-70000kg90532-9458
Flowmeter F100 3" 0-180000kg90532-9459
   
 Clamp - Ethernet IP - EHEDG
Tri-clamp process connection
Ethernet IP
Polished measuring tubes 0.76um EHEDG design
0.1% accuracy
2XM12 electrical connection IP69K
Ultracompact stainless steel housing
Special density application package
_________________________________
Flowmeter F100 1/2" 0-6500kg 90532-9460 
Flowmeter F100 1" 0-18000kg90532-9461
Flowmeter F100 1-1/2" 0-45000kg90532-9462
Flowmeter F100 2" 0-70000kg90532-9463
Flowmeter F100 3" 0-180000kg90532-9464
   

Promass F 300 - Clamp
 DescriptionDenominationPart NoAdd to cart
 Tri-Clamp
Material: EN 1.4404/316/316L
0.1% accuracy
4_20 mA HART/Frequency
Touch button display
El.connection: Gland M20 IP68
Stainless Steel Housing
_________________________________
Promass F300 Tri-Cl.1" 0-18000kg 90529-7966 
Promass F300 Tri-Cl.1/2" 0-6500kg 90529-7962
Promass F300 Tri-Cl.3" 0-180000kg90529-7980
   

Promass Q 300 - Clamp
 DescriptionDenominationPart NoAdd to cart
 Tri-clamp, with display
Material EN 1.4404/316/316L
0.1% accuracy
Profinet IO
El.connection: Thread M20 IP69K
Stainless Steel Housing
Promass Q300 Tri-Cl.1" w display 90531-0153 
Promass Q300 Tri-Cl.2" w display90531-0154
   
 Tri-Clamp, without display
Material EN 1.4404/316/316L
0.1% accuracy
Profinet IO
El.connection: Thread M20 IP69K
Stainless Steel Housing
_________________________________
Promass Q300 Tri-Cl.1" 90529-4522 
Promass Q300 Tri-Cl.2"90529-4521
   

Promag Q 300 - Union
 DescriptionDenominationPart NoAdd to cart
 SMS union, with display
Material EN 1.4404/316/316L
0.1% accuracy
Profinet IO
El.connection: Thread M20 IP69K
Stainless Steel Housing
Promass Q300 SMS25 w display 90531-0155 
Promass Q300 SMS51 w display90531-0156
   
 SMS union, without display
Material EN 1.4404/316/316L
0.1% accuracy
Profinet IO
El.connection: Thread M20 IP69K
Stainless Steel Housing
_________________________________
Promass Q300 SMS25 90531-0157 
Promass Q300 SMS5190531-0158
   

 

© Copyright Tetra Pak ®
Disclaimer
Cookie policy